The engineering manager of a mine shall ensure that each 
(a) air receiver in the mine is marked in a manner that makes the mark clearly visible with the year of manufacture and the authorised working pressure of that air receiver;
(b) air receiver used for the storage of air or gas;
(i) is of sound construction and properly maintained to the satisfaction of the inspector, and
(ii) is where required by the inspector fitted with an apparatus for showing the pressure of the air or gas contained in it, and
(iii) is fitted with a safety valve and where there is no receiver on the surface, the pressure guage and safety valve are where appropriate fitted to the pipe conveying the air or gas.